| Error Code | Meaning | Safe first steps | Technician required | Related help |
|---|---|---|---|---|
| F001 / F002 / F004 / F005 | [790 4-digit range] Touch panel failure | Disconnect power for 30 seconds and retry once. | Yes | |
| F003 | [790 4-digit range] User interface control board failure | Disconnect power. If code returns, service should replace the UI board. | Yes | |
| F010 | [790 4-digit range] Runaway temperature / overheating | Shut off power immediately. Do not continue use until sensor/control is checked. | Yes | |
| F011 | [790 4-digit range] Stuck key on keypad | Press Stop and make sure nothing is pressing keypad. If code remains, service is needed. | Yes | |
| F013 | [790 4-digit range] User interface control board failure | Disconnect power for 30 seconds and retry once. | Yes | |
| F015 | [790 4-digit range] Touch panel failure | Disconnect power for 30 seconds and retry once. | Yes | |
| F017 | [790 4-digit range] UI board unable to configure touch panel | Disconnect power. If wiring is not obviously loose or wrong replacement part not involved, service is needed. | Yes | |
| F018 | [790 4-digit range] Relay control board failure | Disconnect electrical power and stop use. | Yes | |
| F030 / F031 | [790 4-digit range] Oven temperature sensor probe failure | Disconnect power. If sensor resistance is out of spec, service should replace sensor. | Yes | |
| F050 | [790 4-digit range] Relay board cannot detect door lock switch status | Disconnect power and avoid self-clean until serviced. | Yes | |
| F090 | [790 4-digit range] Door lock error | Disconnect power, restore once, and retry door lock only one time. | Yes | |
| F095 | [790 4-digit range] Door lock motor does not stop running | Disconnect power immediately and stop use. | Yes | |
| F10 | [Glass-touch range / Elite slide-in] Runaway temperature / overheating | Disconnect power immediately. Do not continue use until service checks sensor/control. | Yes | |
| F11 | [Glass-touch range] Defective glass touch panel | Disconnect power for 30 seconds and retry once. | Yes | |
| F12 / F13 / F15 / F16 / F17 / F18 / LinE ERR | [Glass-touch range] Electronic oven control board failure | Disconnect power for 30 seconds and retry once. | Yes | |
| F20 | [Glass-touch range] Communication failure between oven control and surface burner control system | Disconnect power. Because live-voltage checks may be required, service is recommended. | Yes | |
| F23 / F24 | [Glass-touch range] Communication failure between convection fan speed control board and oven control | Disconnect power and stop use until serviced. | Yes | |
| F30 / F31 | [Glass-touch range] Oven temperature sensor failure | Disconnect power. Service should verify sensor circuit and EOC if needed. | Yes | |
| F90 / F91 / F92 / F93 / F94 / F95 | [Glass-touch range] Oven door lock failure | Disconnect power and avoid self-clean until serviced. | Yes | |
| F1 | [Self-cleaning wall oven / 665 wall oven-range] Oven temperature sensor or electronic oven control failure | Unplug for 30 seconds and retry once. | Yes | |
| F2/E0 | [665 range / wall oven] Keypad wire harness disconnected | Disconnect power and reseat only an obviously loose accessible harness if safe. | Yes | |
| F2/E5 or F2/E6 | [665 range / wall oven] Cancel key defective | Disconnect power and retry after reset. If code returns, service is needed. | Yes | |
| F3/E0 | [665 range / wall oven] Oven temperature sensor defective or open circuit | Disconnect power and stop use until sensor circuit is checked. | Yes | |
| F3/E1 | [665 range / wall oven] Oven temperature sensor defective or shorted circuit | Disconnect power and stop use until sensor circuit is checked. | Yes | |
| F9 | [Self-cleaning wall oven] Oven door lock failure | Unplug unit and avoid self-clean until serviced. | Yes |
Kenmore Range and Wall Oven Codes Across Control Platforms
Compare Kenmore range and wall oven codes used on 790-series, glass-touch, and 665-series controls. Identify warnings tied to the keypad, control boards, runaway heat, temperature sensing, module communication, convection fan, and door-lock assembly, with clear guidance on when San Diego homeowners should disconnect power and request diagnosis.